Myson Low-E2 Radiators
A fresh approach to
home comfort

Myson Lowu-E2 IS A HEAT PUMP CONVECTOR THAT COMBINES HEATING
AND COOLING IN ONE PRODUCT

ULOW-E2
The ULOW-E2 is the ultimate choice when it comes to intelligent, low temperature heating. It uses in-built fans to force convection and produces heat outputs up to 60% more than traditional radiators. It has intelligent controls allowing the fans to work on a sliding scale where the water temperature must be 3°C higher than the set point. It is highly flexible, utilizing central connection technology and has a “summer breeze” function for air circulation on warm days.
-
The MYSON ULOW-E2 is available in nine sizes
-
It is available in one type, double panel with factory fitted top grille and side panels as standard
-
It comes in a height of 600mm
-
We offer lengths from 400mm to 2000mm
-
All our ULOW-E2 radiators come with a white electronic thermostatic actuator
-
Central connection twin entry valve and nut & olive pack supplied separately



Low temperature compatible
The ULOW-E2 provides enhanced convection via in-built fans. This enables heat sources to operate at their most energy efficient settings. The result is a heating concept that can provide high heat outputs even at lower water temperatures.
Rapid response heating
Due to its combination of both radiant heat and enhanced convection, plus intelligent controls that automatically switch between static and dynamic operation, the ULOW-E2 provides a rapid heat response even at low water temperatures. Indoor comfort is quickly and efficiently achieved.
Intelligent controls
The E2 technology automatically and intelligently controls operation of the in-built fans to ensure maximum performance. The intelligence behind the ULOW-E2 means that the fans will only operate when they are required.


CLICK TO DOWNLOAD
MORE INFORMATION
OTHER BENEFITS OF THE
Myson Low-E2
CONTROLS
Myso offers a wide variety of controllers that are functional and have a great design.
FAST AND HIGH CAPACITY
The Myson combines the advantages of residential underfloor heating and radiators. It delivers high capacity heating or cooling faster and at ultra-low temperatures (35/30° regime)
MODULATED AIR FLOW
When there is less heating demand, the unit modulates its airflow to slow down the fan rate, and in the process, lowers the operational sound. A standard ON/OFF fan running simultaneously at full speed can drastically increase the noise
DC INVERTER
Myson uses the latest technologies to consume less electricity while maintaining its reliable performance







